ESP_a170 — Ax Signal Frozen
Full alert identifier: ESP_a170_axSignalFrozen
Alert description
Longitudinal Acceleration Sensor: Plausibility against second signal failed
Potential impact
May fault VDC/TC, ABS performance degradation
Set condition
Inertial signal failed plausibility/integrity checks
Clear condition
Inertial messages are present/valid on the bus. Review RCM/DI alerts for other indicators of failure
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of ESP_a170.