Alert description

The front trunk (frunk) follower strut experiences a current spike.

Potential impact

This alert is primarily informational and is used for logging purposes. No expected impact on vehicle functionality.

Set condition

There is an unexpected current spike on the frunk follower strut2.

Clear condition

The frunk is requested to move.

Signals to check

These diagnostic fields are associated with EGGRIGHT1_a580. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Frunk Follower Latch Status EGGRIGHT1_a580_frunkFollowerLatchStatus —
Frunk Follower Position EGGRIGHT1_a580_frunkFollowerPosition deg
Frunk Follower Strut Current A EGGRIGHT1_a580_frunkFollowerStrutCurrentA A
Frunk Follower Strut Current Rate EGGRIGHT1_a580_frunkFollowerStrutCurrentRate A/s
Shadow Alert EGGRIGHT1_a580_shadowAlert —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGRIGHT1_a580.