EGGRIGHT1_a455 — Frunk Strut Actuator Undercurrent
Full alert identifier: EGGRIGHT1_a455_frunkStrutActuatorUndercurrent
Alert description
The vehicle controller detects an undercurrent condition on the front trunk (or frunk) strut actuator, indicating the 48V rail may be down.
Potential impact
The front trunk strut may be unable to actuate, preventing the front trunk from opening or closing.
Set condition
Firmware is commanding the frunk strut to actuate but the strut actuator draws less than 50mA for 300ms, and the velocity of the actuator is less than 1 deg/s.
Clear condition
The front trunk strut actuator draws more than 50mA, or firmware stops attempting to actuate the frunk strut.
Signals to check
These diagnostic fields are associated with EGGRIGHT1_a455. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
48 V SW Voltage
EGGRIGHT1_
|
V |
Liftgate Position
EGGRIGHT1_
|
deg |
Liftgate State
EGGRIGHT1_
|
— |
Liftgate Strut Current
EGGRIGHT1_
|
A |
Liftgate Strut Duty
EGGRIGHT1_
|
% |
Liftgate Velocity
EGGRIGHT1_
|
deg/s |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGRIGHT1_a455.