EGGRIGHT1_a415 — Undervoltage Self Test Stuck Off

Full alert identifier: EGGRIGHT1_a415_undervoltageSelfTestStuckOff

Alert description

One or more loads failed to turn on during the Right Domain Undervoltage Self-Test. Those loads will be inhibited from use in drive.

Potential impact

Impacted load(s) will not be usable in drive.

Set condition

One or more loads failed to turn on during the Right Domain Undervoltage Self-Test.

Clear condition

The Right Domain Undervoltage self-test is ran again and the load is turned on successfully.

Signals to check

These diagnostic fields are associated with EGGRIGHT1_a415. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Vbus 16 V Air Susp Stuck Off EGGRIGHT1_a415_vbus16vAirSuspStuckOff —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGRIGHT1_a415.

Browse all EGGRIGHT1 alert codes