EGGRIGHT1_a257 — Seat Abuse Motor Stop
Full alert identifier: EGGRIGHT1_a257_seatAbuseMotorStop
Alert description
The seat has detected that the track motor has exceeded normal operating times
Potential impact
The seat track motor will be disabled
Set condition
The operating time has exceeded 120 seconds within 5 minutes
Clear condition
Elapsed time greater than 5 minutes since last operation
Signals to check
These diagnostic fields are associated with EGGRIGHT1_a257. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Cabin Tmp
EGGRIGHT1_
|
degC |
Seat Motor Calibrated
EGGRIGHT1_
|
— |
Seat Motor Current
EGGRIGHT1_
|
A |
Seat Motor Pos Real
EGGRIGHT1_
|
mm |
Seat Motor State
EGGRIGHT1_
|
— |
Seat Switch Back
EGGRIGHT1_
|
— |
Seat Switch Forward
EGGRIGHT1_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGRIGHT1_a257.