EGGRIGHT1_a140 — TAS damper Valve Rbnd FR
Full alert identifier: EGGRIGHT1_a140_TAS_damperValveRbndFR
Alert description
The front right rebound damper valve experienced a condition affecting its operation.
Potential impact
No dampers will be powered.
Set condition
Front right rebound damper valve detected to be unplugged, shorted, pin-swapped, or it encountered an internal condition.
Clear condition
Vehicle power state cycles from OFF to ON.
Signals to check
These diagnostic fields are associated with EGGRIGHT1_a140. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Damper Valve Fault
EGGRIGHT1_
|
— |
Device On State Diagnostics
EGGRIGHT1_
|
— |
Drv Device Fault
EGGRIGHT1_
|
— |
Drv Device Over Current
EGGRIGHT1_
|
— |
Drv Device Over Temperature
EGGRIGHT1_
|
— |
Drv Device Over Voltage
EGGRIGHT1_
|
— |
Drv Device Spi Comm Error
EGGRIGHT1_
|
— |
Drv Device Under Voltage
EGGRIGHT1_
|
— |
Show 6 more fields
| Signal | Unit |
|---|---|
Drv Failed Communication
EGGRIGHT1_
|
— |
Drv Output Gnd Short
EGGRIGHT1_
|
— |
Drv Output Open Circuit
EGGRIGHT1_
|
— |
Drv Output Over Current
EGGRIGHT1_
|
— |
Drv Output Vm Short
EGGRIGHT1_
|
— |
Drv Power On Reset
EGGRIGHT1_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGRIGHT1_a140.