Skip to content

EGGRIGHT1_a139 — TAS damper Valve Comp FR

Full alert identifier: EGGRIGHT1_a139_TAS_damperValveCompFR

Alert description

The front right compression damper valve experienced a condition affecting its operation.

Potential impact

No dampers will be powered.

Set condition

Front right compression damper valve detected to be unplugged, shorted, pin-swapped, or it encountered an internal condition.

Clear condition

Vehicle power state cycles from OFF to ON.

Signals to check

These diagnostic fields are associated with EGGRIGHT1_a139. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Damper Valve Fault EGGRIGHT1_a139_damperValveFault —
Device On State Diagnostics EGGRIGHT1_a139_deviceOnStateDiagnostics —
Drv Device Fault EGGRIGHT1_a139_drvDeviceFault —
Drv Device Over Current EGGRIGHT1_a139_drvDeviceOverCurrent —
Drv Device Over Temperature EGGRIGHT1_a139_drvDeviceOverTemperature —
Drv Device Over Voltage EGGRIGHT1_a139_drvDeviceOverVoltage —
Drv Device Spi Comm Error EGGRIGHT1_a139_drvDeviceSpiCommError —
Drv Device Under Voltage EGGRIGHT1_a139_drvDeviceUnderVoltage —
Show 6 more fields
Signal Unit
Drv Failed Communication EGGRIGHT1_a139_drvFailedCommunication —
Drv Output Gnd Short EGGRIGHT1_a139_drvOutputGndShort —
Drv Output Open Circuit EGGRIGHT1_a139_drvOutputOpenCircuit —
Drv Output Over Current EGGRIGHT1_a139_drvOutputOverCurrent —
Drv Output Vm Short EGGRIGHT1_a139_drvOutputVmShort —
Drv Power On Reset EGGRIGHT1_a139_drvPowerOnReset —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGRIGHT1_a139.

Browse all EGGRIGHT1 alert codes