EGGRIGHT1_a121 — eFuse Management Non Continuous48 V

Full alert identifier: EGGRIGHT1_a121_eFuseManagementNonContinuous48V

Alert description

Unexpected voltage seen on non-continuous device outputs

Potential impact

Electrical loads for frunk strut and frunk motor control may be unavailable.

Set condition

Voltage is above 35V for 10 seconds on at least one of the device outputs while none of them are being driven

Clear condition

Voltage is below 35V and 10 seconds have passed since alert was set. If the alert sets 3 or more times, controller reset is required.

Signals to check

These diagnostic fields are associated with EGGRIGHT1_a121. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
E Fuse Trip Count EGGRIGHT1_a121_eFuseTripCount —
Non Continuous 48 VE Fuse Monitor EGGRIGHT1_a121_nonContinuous48VEFuseMonitor V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGRIGHT1_a121.