EGGRIGHT1_a121 — eFuse Management Non Continuous48 V
Full alert identifier: EGGRIGHT1_a121_eFuseManagementNonContinuous48V
Alert description
Unexpected voltage seen on non-continuous device outputs
Potential impact
Electrical loads for frunk strut and frunk motor control may be unavailable.
Set condition
Voltage is above 35V for 10 seconds on at least one of the device outputs while none of them are being driven
Clear condition
Voltage is below 35V and 10 seconds have passed since alert was set. If the alert sets 3 or more times, controller reset is required.
Signals to check
These diagnostic fields are associated with EGGRIGHT1_a121. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
E Fuse Trip Count
EGGRIGHT1_
|
— |
Non Continuous 48 VE Fuse Monitor
EGGRIGHT1_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGRIGHT1_a121.