Alert description

Audio amplifier 2 reports an overcurrent error on one or more of its channels. This alert can indicate a condition affecting the amplifier hardware.

Potential impact

One or more of the amplifier channels is not operating as expected. Audio will not operate as expected, and the amplifier may be shorted.

Set condition

Amplifier 2 reports one or more of its channels is overcurrent.

Clear condition

Amplifier 2 does not report a single channel overcurrent across all channels for 5 seconds.

Signals to check

These diagnostic fields are associated with EGGREAR_a065. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Ch 1 Overcurrent EGGREAR_a065_ch1_overcurrent —
Ch 2 Overcurrent EGGREAR_a065_ch2_overcurrent —
Ch 3 Overcurrent EGGREAR_a065_ch3_overcurrent —
Ch 4 Overcurrent EGGREAR_a065_ch4_overcurrent —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGREAR_a065.