Skip to content

EGGREAR_a055 — Amplifier2 Faults

Full alert identifier: EGGREAR_a055_amplifier2Faults

Alert description

The Ethernet Generalized Gateway (EGGxxx) detects a condition affecting the health of the second amplifier.

Potential impact

Audio quality may decrease.

Set condition

An amplifier condition is reported on second amp. Alert log signal data should provide more information on the specific condition(s) detected.

Clear condition

An amplifier condition is no longer reported on second amp.

Signals to check

These diagnostic fields are associated with EGGREAR_a055. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Channel Dc Fault Ch 1 EGGREAR_a055_channelDcFaultCh1 —
Channel Dc Fault Ch 2 EGGREAR_a055_channelDcFaultCh2 —
Channel Dc Fault Ch 3 EGGREAR_a055_channelDcFaultCh3 —
Channel Dc Fault Ch 4 EGGREAR_a055_channelDcFaultCh4 —
Channel Over Current Ch 1 EGGREAR_a055_channelOverCurrentCh1 —
Channel Over Current Ch 2 EGGREAR_a055_channelOverCurrentCh2 —
Channel Over Current Ch 3 EGGREAR_a055_channelOverCurrentCh3 —
Channel Over Current Ch 4 EGGREAR_a055_channelOverCurrentCh4 —
Show 14 more fields
Signal Unit
Clock Error EGGREAR_a055_clockError —
Over Temperature Shutdown Ch 1 EGGREAR_a055_overTemperatureShutdownCh1 —
Over Temperature Shutdown Ch 2 EGGREAR_a055_overTemperatureShutdownCh2 —
Over Temperature Shutdown Ch 3 EGGREAR_a055_overTemperatureShutdownCh3 —
Over Temperature Shutdown Ch 4 EGGREAR_a055_overTemperatureShutdownCh4 —
Over Temperature Shutdown Global EGGREAR_a055_overTemperatureShutdownGlobal —
Over Temperature Warning Ch 1 EGGREAR_a055_overTemperatureWarningCh1 —
Over Temperature Warning Ch 2 EGGREAR_a055_overTemperatureWarningCh2 —
Over Temperature Warning Ch 3 EGGREAR_a055_overTemperatureWarningCh3 —
Over Temperature Warning Ch 4 EGGREAR_a055_overTemperatureWarningCh4 —
Over Temperature Warning Global EGGREAR_a055_overTemperatureWarningGlobal —
Pvdd Error EGGREAR_a055_pvddError
0
NO ERROR
1
UNDERVOLTAGE
2
OVERVOLTAGE
—
Vbat Error EGGREAR_a055_vbatError
0
NO ERROR
1
UNDERVOLTAGE
2
OVERVOLTAGE
—
Vdd Power On Reset EGGREAR_a055_vddPowerOnReset —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGREAR_a055.

Browse all EGGREAR alert codes