EGGREAR1_a568 — Tonneau Right Motor Overuse Buffer Warn

Full alert identifier: EGGREAR1_a568_tonneauRightMotorOveruseBufferWarn

Alert description

Right tonneau motor overuse has been detected, with number of events within 5 minutes required to generate a warning exceeded

Potential impact

The right tonneau motor will be disabled if operation continues and maximum number of events within 5 minutes is exceeded

Set condition

The number of operating events per time period required to generate a warning for right tonneau motor overuse has been exceeded

Clear condition

Elapsed time greater than 5 minutes since last operation

Signals to check

These diagnostic fields are associated with EGGREAR1_a568. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Tonneau Motor Calibrated EGGREAR1_a568_tonneauMotorCalibrated —
Tonneau Motor Current A EGGREAR1_a568_tonneauMotorCurrentA A
Tonneau Motor Position MM EGGREAR1_a568_tonneauMotorPositionMM mm
Tonneau Motor State EGGREAR1_a568_tonneauMotorState —
Tonneau Motor Stop Reason EGGREAR1_a568_tonneauMotorStopReason —