EGGREAR1_a566 — Tonneau Right Motor Overuse Stop

Full alert identifier: EGGREAR1_a566_tonneauRightMotorOveruseStop

Alert description

The tonneau controller has detected that the right tonneau motor has exceeded normal operating times

Potential impact

The right tonneau motor will be disabled

Set condition

The operating time has exceeded 90 seconds within 4.5 minutes

Clear condition

Elapsed time greater than 4.5 minutes since last operation

Signals to check

These diagnostic fields are associated with EGGREAR1_a566. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Tonneau Motor Calibrated EGGREAR1_a566_tonneauMotorCalibrated —
Tonneau Motor Current A EGGREAR1_a566_tonneauMotorCurrentA A
Tonneau Motor Position MM EGGREAR1_a566_tonneauMotorPositionMM mm
Tonneau Motor State EGGREAR1_a566_tonneauMotorState —
Tonneau Motor Stop Reason EGGREAR1_a566_tonneauMotorStopReason —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGREAR1_a566.

Browse all EGGREAR1 alert codes