EGGLEFT_a064 — Amplifier Channel Over Current
Full alert identifier: EGGLEFT_a064_amplifierChannelOverCurrent
Alert description
The amplifier reports an overcurrent error on one or more of its channels. This alert can indicate a condition affecting the amplifier hardware.
Potential impact
One or more of the amplifier channels is not operating as expected. Audio will not operate as expected, and the amplifier may be shorted.
Set condition
The amplifier reports one or more of its channels is overcurrent.
Clear condition
Amplifier does not report a single channel overcurrent across all channels for 5 seconds.
Signals to check
These diagnostic fields are associated with EGGLEFT_a064. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Ch 1 Overcurrent
EGGLEFT_
|
— |
Ch 2 Overcurrent
EGGLEFT_
|
— |
Ch 3 Overcurrent
EGGLEFT_
|
— |
Ch 4 Overcurrent
EGGLEFT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGLEFT_a064.