Skip to content

EGGLEFT_a054 — Amplifier Faults

Full alert identifier: EGGLEFT_a054_amplifierFaults

Alert description

The Ethernet Generalized Gateway (EGGxxx) detects a condition affecting the health of the amplifier.

Potential impact

Audio quality may decrease.

Set condition

An amplifier condition is reported. Alert log signal data should provide more information on the specific condition(s) detected.

Clear condition

An amplifier condition is no longer reported.

Signals to check

These diagnostic fields are associated with EGGLEFT_a054. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Channel Dc Fault Ch 1 EGGLEFT_a054_channelDcFaultCh1 —
Channel Dc Fault Ch 2 EGGLEFT_a054_channelDcFaultCh2 —
Channel Dc Fault Ch 3 EGGLEFT_a054_channelDcFaultCh3 —
Channel Dc Fault Ch 4 EGGLEFT_a054_channelDcFaultCh4 —
Channel Over Current Ch 1 EGGLEFT_a054_channelOverCurrentCh1 —
Channel Over Current Ch 2 EGGLEFT_a054_channelOverCurrentCh2 —
Channel Over Current Ch 3 EGGLEFT_a054_channelOverCurrentCh3 —
Channel Over Current Ch 4 EGGLEFT_a054_channelOverCurrentCh4 —
Show 14 more fields
Signal Unit
Clock Error EGGLEFT_a054_clockError —
Over Temperature Shutdown Ch 1 EGGLEFT_a054_overTemperatureShutdownCh1 —
Over Temperature Shutdown Ch 2 EGGLEFT_a054_overTemperatureShutdownCh2 —
Over Temperature Shutdown Ch 3 EGGLEFT_a054_overTemperatureShutdownCh3 —
Over Temperature Shutdown Ch 4 EGGLEFT_a054_overTemperatureShutdownCh4 —
Over Temperature Shutdown Global EGGLEFT_a054_overTemperatureShutdownGlobal —
Over Temperature Warning Ch 1 EGGLEFT_a054_overTemperatureWarningCh1 —
Over Temperature Warning Ch 2 EGGLEFT_a054_overTemperatureWarningCh2 —
Over Temperature Warning Ch 3 EGGLEFT_a054_overTemperatureWarningCh3 —
Over Temperature Warning Ch 4 EGGLEFT_a054_overTemperatureWarningCh4 —
Over Temperature Warning Global EGGLEFT_a054_overTemperatureWarningGlobal —
Pvdd Error EGGLEFT_a054_pvddError
0
NO ERROR
1
UNDERVOLTAGE
2
OVERVOLTAGE
—
Vbat Error EGGLEFT_a054_vbatError
0
NO ERROR
1
UNDERVOLTAGE
2
OVERVOLTAGE
—
Vdd Power On Reset EGGLEFT_a054_vddPowerOnReset —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGLEFT_a054.

Browse all EGGLEFT alert codes