EGGLEFTVC_a455 — Frunk Strut Actuator Undercurrent
Full alert identifier: EGGLEFTVC_a455_frunkStrutActuatorUndercurrent
Alert description
The vehicle controller detects an undercurrent condition on the front trunk (or frunk) strut actuator, indicating the 48V rail may be down.
Potential impact
The front trunk strut may be unable to actuate, preventing the front trunk from opening or closing.
Set condition
Firmware is commanding the frunk strut to actuate but the strut actuator draws less than 50mA for 300ms, and the velocity of the actuator is less than 1 deg/s.
Clear condition
The front trunk strut actuator draws more than 50mA, or firmware stops attempting to actuate the frunk strut.
Signals to check
These diagnostic fields are associated with EGGLEFTVC_a455. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
48 V SW Voltage
EGGLEFTVC_
|
V |
Liftgate Position
EGGLEFTVC_
|
deg |
Liftgate State
EGGLEFTVC_
|
— |
Liftgate Strut Current
EGGLEFTVC_
|
A |
Liftgate Strut Duty
EGGLEFTVC_
|
% |
Liftgate Velocity
EGGLEFTVC_
|
deg/s |