Skip to content

EGGLEFTVC_a354 — Frunk Uncalibrated

Full alert identifier: EGGLEFTVC_a354_frunkUncalibrated

Alert description

The frunk has become uncalibrated

Potential impact

The frunk will not be able to actuate open

Set condition

The frunk latch became closed while opened at an unexpected angle

Clear condition

The next time the frunk becomes calibrated

Signals to check

These diagnostic fields are associated with EGGLEFTVC_a354. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Frunk Latch Status EGGLEFTVC_a354_frunkLatchStatus —
Frunk Position EGGLEFTVC_a354_frunkPosition deg
Frunk State EGGLEFTVC_a354_frunkState —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGLEFTVC_a354.

Browse all EGGLEFTVC alert codes