Skip to content

EGGLEFTVC_a359 — Frunk Latch Exit No Position Change

Full alert identifier: EGGLEFTVC_a359_frunkLatchExitNoPositionChange

Alert description

No position change on frunk latch exit, so the encoder has likely stalled

Potential impact

The frunk will not be able to actuate open

Set condition

No encoder movement was seen after a latch exit

Clear condition

The next time the frunk encoder is no longer stalled

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGLEFTVC_a359.