Skip to content

EGGLEFTVC_a205 — Epbm Over I Dyn

Full alert identifier: EGGLEFTVC_a205_epbmOverIDyn

Alert description

Electronic Parking Brake Monitor measured more current than is required for Electronic Parking Brake to remain in DYNAMIC_APPLYING.

Potential impact

The caliper may have a higher than expected braking force.

Set condition

Electronic Parking Brake attempted to remain in DYNAMIC_APPLYING while Electronic Parking Brake Monitor had measured more than the maximum current allowed to remain in DYNAMIC_APPLYING.

Clear condition

A new Electronic Parking Brake operation starts.

Signals to check

These diagnostic fields are associated with EGGLEFTVC_a205. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Current EGGLEFTVC_a205_current A
Desync Count EGGLEFTVC_a205_desyncCount —
Dyn Apply Allowed EGGLEFTVC_a205_dynApplyAllowed —
Dynamic Allowed EGGLEFTVC_a205_dynamicAllowed —
Epb Config EGGLEFTVC_a205_epbConfig —
Open Allowed EGGLEFTVC_a205_openAllowed —
Park Allowed EGGLEFTVC_a205_parkAllowed —
Park Pending Allowed EGGLEFTVC_a205_parkPendingAllowed —
Show 8 more fields
Signal Unit
Parking Allowed EGGLEFTVC_a205_parkingAllowed —
Release Allowed EGGLEFTVC_a205_releaseAllowed —
Service Allowed EGGLEFTVC_a205_serviceAllowed —
Start Allowed EGGLEFTVC_a205_startAllowed —
Unknown Allowed EGGLEFTVC_a205_unknownAllowed —
Wench Pending Allowed EGGLEFTVC_a205_wenchPendingAllowed —
Winch Allowed EGGLEFTVC_a205_winchAllowed —
Winch Release Allowed EGGLEFTVC_a205_winchReleaseAllowed —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGLEFTVC_a205.

Browse all EGGLEFTVC alert codes