EGGLEFTVC_a203 — Epbm Over I Static
Full alert identifier: EGGLEFTVC_a203_epbmOverIStatic
Alert description
Electronic Parking Brake Monitor measured more current than is required for Electronic Parking Brake to remain in PARKING.
Potential impact
Caliper lifetime may be degraded.
Set condition
Electronic Parking Brake attempted to remain in PARKING while Electronic Parking Brake Monitor had measured more than the maximum current allowed to remain in PARKING.
Clear condition
A new Electronic Parking Brake operation starts.
Signals to check
These diagnostic fields are associated with EGGLEFTVC_a203. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Current
EGGLEFTVC_
|
A |
Desync Count
EGGLEFTVC_
|
— |
Dyn Apply Allowed
EGGLEFTVC_
|
— |
Dynamic Allowed
EGGLEFTVC_
|
— |
Epb Config
EGGLEFTVC_
|
— |
Open Allowed
EGGLEFTVC_
|
— |
Park Allowed
EGGLEFTVC_
|
— |
Park Pending Allowed
EGGLEFTVC_
|
— |
Show 8 more fields
| Signal | Unit |
|---|---|
Parking Allowed
EGGLEFTVC_
|
— |
Release Allowed
EGGLEFTVC_
|
— |
Service Allowed
EGGLEFTVC_
|
— |
Start Allowed
EGGLEFTVC_
|
— |
Unknown Allowed
EGGLEFTVC_
|
— |
Wench Pending Allowed
EGGLEFTVC_
|
— |
Winch Allowed
EGGLEFTVC_
|
— |
Winch Release Allowed
EGGLEFTVC_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGLEFTVC_a203.