Skip to content

DIR_a244 — Mech Safe State Applied

Full alert identifier: DIR_a244_mechSafeStateApplied

Alert description

Alert for software trigger of mechanical safe state two-phase disconnect device.

Potential impact

The motor is permanently disabled.

Set condition

Software detects a shorted semiconductor switch. The alert log signals provide detailed trigger algorithm info.

Clear condition

Clears when low voltage (LV) power is removed from drive unit or a non-drive/drive cycle occurs

Signals to check

These diagnostic fields are associated with DIR_a244. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Desat High Side DIR_a244_desatHighSide —
Desat Low Side DIR_a244_desatLowSide —
Flyback Fault DIR_a244_flybackFault —
Gate Drive IC Undervoltage DIR_a244_gateDriveICUndervoltage —
Ir Sensor V DIR_a244_irSensorV V
Plausible Single Switch Short Only DIR_a244_plausibleSingleSwitchShortOnly —
Post Short Test Failed DIR_a244_postShortTestFailed —
Single Switch Short DIR_a244_singleSwitchShort —
Show 1 more field
Signal Unit
Uds Self Test DIR_a244_udsSelfTest —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIR_a244.

Browse all DIR alert codes