Skip to content

DIR_a016 — Safe State Applied

Full alert identifier: DIR_a016_safeStateApplied

Alert description

The Drive Inverter (DIx) power stage has applied a safe state.

Potential impact

Some DIx features may be disabled, or may not function expected. The Drive Unit may not function as expected.

Set condition

The DIx power stage has applied a safe state.

Clear condition

The DIx no longer applies a safe state.

Signals to check

These diagnostic fields are associated with DIR_a016. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Asc Monitor DIR_a016_ascMonitor —
Gate Drive Fault Line DIR_a016_gateDriveFaultLine —
Motor RPM DIR_a016_motorRPM RPM
New Safe State DIR_a016_newSafeState
0
NONE
1
ALL OFF
2
3PS HIGH
3
3PS LOW
—
Old Safe State DIR_a016_oldSafeState
0
NONE
1
ALL OFF
2
3PS HIGH
3
3PS LOW
—
Pedal Monitor Pre Watchdog DIR_a016_pedalMonitorPreWatchdog —
Safety I Cfault Line DIR_a016_safetyICfaultLine —
Torque Motor DIR_a016_torqueMotor Nm
Show 2 more fields
Signal Unit
Trigger Event DIR_a016_triggerEvent —
Uncontrolled Regen Zone DIR_a016_uncontrolledRegenZone —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIR_a016.