Skip to content

DIRER_a012 — Hvil Not Closed

Full alert identifier: DIRER_a012_hvilNotClosed

Alert description

Drive Inverter Warning: HVIL not CLOSED

Potential impact

Contactors may not close

Set condition

HVIL is no longer CLOSED

Clear condition

HVIL closing again

Signals to check

These diagnostic fields are associated with DIRER_a012. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Active Dis On 3 V 3 DIRER_a012_activeDisOn3V3 —
Hvil Fault Gpio DIRER_a012_hvilFaultGpio —
Hvil Header Fault DIRER_a012_hvilHeaderFault —
Hvil IO N DIRER_a012_hvilIO_N —
Hvil Status DIRER_a012_hvilStatus
0
DISABLED
1
OPEN
2
CLOSED
3
SNA
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIRER_a012.

Browse all DIRER alert codes