DIRER_a011 — Sw Power Stage Not Ready
Full alert identifier: DIRER_a011_swPowerStageNotReady
Alert description
The Drive Inverter (DIx) power stage is not ready. There may be a condition affecting the DIx control board.
Potential impact
DIx may not function as expected.
Set condition
The DIx power stage is not ready. One of the pre-drive gate driver checks has failed. There may be a condition affecting the DIx control board.
Clear condition
The DIx power stage is ready and functions as expected.
Signals to check
These diagnostic fields are associated with DIRER_a011. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Bad Data Expected
DIRER_
|
— |
Bad Data Read
DIRER_
|
— |
Bad Gate Drive IC
DIRER_
|
— |
Code Branch
DIRER_
|
— |
Phase A High
DIRER_
|
— |
Phase A Low
DIRER_
|
— |
Phase B High
DIRER_
|
— |
Phase B Low
DIRER_
|
— |
Show 4 more fields
| Signal | Unit |
|---|---|
Phase C High
DIRER_
|
— |
Phase C Low
DIRER_
|
— |
Reason
DIRER_
|
— |
Reg Address
DIRER_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIRER_a011.