Skip to content

DIREL_a154 — Resolver

Full alert identifier: DIREL_a154_resolver

Alert description

The Drive Unit resolver (motor speed sensor) is not operating as expected. The resolver may have a condition affecting functionality.

Potential impact

The resolver is not operating as expected. The DIx invertor control board may be unable to correctly detect the angle and speed of the rotor.

Set condition

The Drive Unit resolver is not operating as expected. The resolver may have a condition affecting functionality.

Clear condition

The resolver begins functioning as expected. Review the logs to crack alert.

Signals to check

These diagnostic fields are associated with DIREL_a154. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Carrier Offset DIREL_a154_carrierOffset —
Cla MIA DIREL_a154_claMIA —
Common Gain DIREL_a154_commonGain 1
Error Table Invalid DIREL_a154_errorTableInvalid —
Motor RPM DIREL_a154_motorRPM RPM
No Calibration DIREL_a154_noCalibration —
No Carrier DIREL_a154_noCarrier —
No Phase Lock DIREL_a154_noPhaseLock —
Show 3 more fields
Signal Unit
Not Ready DIREL_a154_notReady —
Phase Error DIREL_a154_phaseError 1
Tracker Irrational DIREL_a154_trackerIrrational —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIREL_a154.

Browse all DIREL alert codes