Skip to content

DIREL_a107 — Fpga Error

Full alert identifier: DIREL_a107_fpgaError

Alert description

The Drive Inverter (DIx) has detected an error communicating with the Field Programmable Gate Array (FPGA).

Potential impact

The DIx Gate Drive Unit may not be able to receive data from the Pedal Monitor. The vehicle's drive cycle may not function as expected.

Set condition

DIx has detected an error communicating with FPGA. There may be a condition affecting the DIx control board functionality.

Clear condition

The DIx no longer detects an error communicating with FPGA. May require DIx be replaced.

Signals to check

These diagnostic fields are associated with DIREL_a107. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Fpga Boot Version DIREL_a107_fpgaBootVersion —
Fpga Fault Active DIREL_a107_fpgaFaultActive —
Fpga Master Active DIREL_a107_fpgaMasterActive —
Fpga Version DIREL_a107_fpgaVersion —
Fpga Warning Active DIREL_a107_fpgaWarningActive —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIREL_a107.

Browse all DIREL alert codes