DIREL_a038 — Bus Vsensor
Full alert identifier: DIREL_a038_busVsensor
Alert description
Drive Inverter Warning: Battery sensor bad
Potential impact
Drive unit enters unit limp mode (see DI_a126_limpMode), faults (Model 3 only)
Set condition
When HV bus is up, DI measured bus voltage very low or disagrees with BMS reported voltage
Clear condition
When HV bus is up, DI measured bus voltage matches BMS reported voltage
Signals to check
These diagnostic fields are associated with DIREL_a038. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
I Bat
DIREL_
|
A |
Reason
DIREL_
|
— |
V BMS
DIREL_
|
V |
V Bat
DIREL_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIREL_a038.