DFLKF_a025 — Position Uncalibrated Or Cal Corrupted
Full alert identifier: DFLKF_a025_positionUncalibratedOrCalCorrupted
Alert description
Position sensor has not yet been calibrated or calibration is corrupted.
Potential impact
Differential Locker (DFLK) functionality will be disabled. Position sense will report as unknown.
Set condition
Calibration value is detected to be uninitialized or corrupted
Clear condition
The Differential Locker (DFLK) position sensor calibration routine is run and completes successfully.
Signals to check
These diagnostic fields are associated with DFLKF_a025. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Ldc Sensor Normalization Offset
DFLKF_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DFLKF_a025.