DFLKF_a005 — Position Sensor Conversion Error

Full alert identifier: DFLKF_a005_positionSensorConversionError

Alert description

Differential Locker (DFLK) coil position sensor has at least one conversion error.

Potential impact

DFLK may not function as expected.

Set condition

Any conversion error bit set in data register.

Clear condition

All four conversion error bits cleared in data register. May require power cycle and/or locker replacement.

Signals to check

These diagnostic fields are associated with DFLKF_a005. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Conversion Amplitude Error DFLKF_a005_conversionAmplitudeError —
Conversion Overrange Error DFLKF_a005_conversionOverrangeError —
Conversion Underrange Error DFLKF_a005_conversionUnderrangeError —
Conversion Watchdog Timeout Error DFLKF_a005_conversionWatchdogTimeoutError —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DFLKF_a005.

Browse all DFLKF alert codes