Skip to content

CP_a054 — Cable Not Secured

Full alert identifier: CP_a054_cableNotSecured

Alert description

Charge port (CP) expects the cable to be secured, but the charge port latch has not secured the cable in place. AC charge rate may be reduced, and DC charging may be unavailable.

Potential impact

AC charge rate may be reduced, and DC charging may be unavailable.

Set condition

A charge cable is detected. The charge port (CP) latch position sensor indicates the latch is disengaged, either after the charge port has attempted to engage the latch or when the latch is already expected to be engaged.

Clear condition

The charge port (CP) latch engages, or the cable is unplugged from the charge port.

Signals to check

These diagnostic fields are associated with CP_a054. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
CHG Insert Enable CP_a054_CHG_InsertEnable —
CP Aps Voltage CP_a054_CP_apsVoltage V
CP Latch Enable Cmd CP_a054_CP_latchEnableCmd —
CP Proximity CP_a054_CP_proximity
0
SNA
1
DISCONNECTED
2
UNLATCHED
3
LATCHED
—
Inlet ID CP_a054_inletID
0
SAE
1
IEC
2
GBAC
3
GBDC
—
Latch Counts Filtered CP_a054_latchCountsFiltered %
Latch State CP_a054_latchState
0
SNA
1
DISENGAGED
2
ENGAGED
3
BLOCKING
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a054.

Browse all CP alert codes