CP_a037 — Latch Not Engaged
Full alert identifier: CP_a037_latchNotEngaged
Alert description
The charge port (CP) latch is expected to be engaged but is not engaged. AC charge rate may be reduced, and DC charging may be unavailable.
Potential impact
The charge port (CP) latch may not engage as expected. AC charge rate may be reduced, and DC charging may be unavailable.
Set condition
The charge port (CP) latch position sensor indicates the latch is disengaged, either after the charge port has attempted to engage the latch or when the latch is already expected to be engaged.
Clear condition
The charge port (CP) latch engages.
Signals to check
These diagnostic fields are associated with CP_a037. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
CHG Insert Enable
CP_
|
— |
CP Aps Voltage
CP_
|
V |
CP Latch Enable Cmd
CP_
|
— |
Inlet ID
CP_
|
— |
Latch Counts Filtered
CP_
|
% |
Latch State
CP_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a037.