Skip to content

CMPT_a139 — Large Current Offset

Full alert identifier: CMPT_a139_largeCurrentOffset

Alert description

A phase current offset of the compressor multiphase motor is greater than the expected variance. Compressor may not operate as expected.

Potential impact

Compressor may not operate as expected. Controller may be damaged.

Set condition

A phase current offset greater than the expected variance is detected.

Clear condition

Current calibration re-runs. Calibration is done during start-up, and the condition may resolve during a vehicle power cycle.

Signals to check

These diagnostic fields are associated with CMPT_a139. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Bus Current Offset CMPT_a139_busCurrentOffset amp
Phase A Current Offset CMPT_a139_phaseACurrentOffset amp
Phase B Current Offset CMPT_a139_phaseBCurrentOffset amp
Phase C Current Offset CMPT_a139_phaseCCurrentOffset amp

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CMPT_a139.

Browse all CMPT alert codes