CC_a001 — Gnd Mon Intrpt Line Side

Full alert identifier: CC_a001_gndMonIntrptLineSide

Alert description

Wall connector protective earth is disconnected or grounding scheme dual in-line package (DIP) switch is set incorrectly.

Potential impact

Wall connector will not allow charging until the protective earth connection is corrected.

Set condition

Wall connector alternating current (AC) input side ground impedance is above threshold.

Clear condition

Wall connector AC input side ground impedance has fallen below threshold for adequate time.

Signals to check

These diagnostic fields are associated with CC_a001. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Ground Resistance CC_a001_groundResistance
4094
NO GROUND
4095
SNA
Ohm

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CC_a001.