Skip to content

APP_w363 — Fascia Camera Stream Exit

Full alert identifier: APP_w363_fasciaCameraStreamExit

Alert description

The fascia camera stream to the Autopilot electronic control unit (ECU) exits or is interrupted, which may cause Autopilot functionality to be limited or unavailable.

Potential impact

Autopilot functionality may be limited or unavailable.

Set condition

The fascia camera stream exits or is interrupted.

Clear condition

The fascia camera stream returns.

Signals to check

These diagnostic fields are associated with APP_w363. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Buffer Error APP_sw363_bufferError —
Current Temperature APP_sw363_currentTemperature
255
SNA
degC
Deser Crc Error APP_sw363_deserCrcError —
Deser Line Length Error APP_sw363_deserLineLengthError —
Deser Lock Error APP_sw363_deserLockError —
Deser Parity Error APP_sw363_deserParityError —
Exit Status APP_sw363_exitStatus
0
NOMINAL
1
FAULT
—
First Frame Grab Failure APP_sw363_firstFrameGrabFailure —
Show 8 more fields
Signal Unit
Frame Grab Failure APP_sw363_frameGrabFailure —
Gain Control Failure APP_sw363_gainControlFailure —
Imager Heartbeat APP_sw363_imagerHeartbeat
0
NOMINAL
1
STATIC
3
SNA
—
Max Temperature APP_sw363_maxTemperature
255
SNA
degC
Min Temperature APP_sw363_minTemperature
255
SNA
degC
Num Capture Recoveries APP_sw363_numCaptureRecoveries —
Serializer Crc Err Count APP_sw363_serializerCrcErrCount
255
SNA
—
Temp Monitor Failure APP_sw363_tempMonitorFailure
0
MONITOR NO FAILURE
1
OUT OF SPEC
2
MONITOR OTHER FAILURE
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of APP_w363.