Skip to content

APP_w182 — Main Camera Stream Exit

Full alert identifier: APP_w182_mainCameraStreamExit

Alert description

The main camera stream to the Autopilot electronic control unit (ECU) exits or is interrupted, which may cause Autopilot functionality to be limited or unavailable.

Potential impact

Autopilot functionality may be limited or unavailable.

Set condition

The main camera stream exits or is interrupted.

Clear condition

The main camera stream returns.

Signals to check

These diagnostic fields are associated with APP_w182. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Buffer Error APP_sw182_bufferError —
Current Temperature APP_sw182_currentTemperature
255
SNA
degC
Deser Crc Error APP_sw182_deserCrcError —
Deser Line Length Error APP_sw182_deserLineLengthError —
Deser Lock Error APP_sw182_deserLockError —
Deser Parity Error APP_sw182_deserParityError —
Exit Status APP_sw182_exitStatus
0
NOMINAL
1
FAULT
—
First Frame Grab Failure APP_sw182_firstFrameGrabFailure —
Show 8 more fields
Signal Unit
Frame Grab Failure APP_sw182_frameGrabFailure —
Gain Control Failure APP_sw182_gainControlFailure —
Imager Heartbeat APP_sw182_imagerHeartbeat
0
NOMINAL
1
STATIC
3
SNA
—
Max Temperature APP_sw182_maxTemperature
255
SNA
degC
Min Temperature APP_sw182_minTemperature
255
SNA
degC
Num Capture Recoveries APP_sw182_numCaptureRecoveries —
Serializer Crc Err Count APP_sw182_serializerCrcErrCount
255
SNA
—
Temp Monitor Failure APP_sw182_tempMonitorFailure
0
MONITOR NO FAILURE
1
OUT OF SPEC
2
MONITOR OTHER FAILURE
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of APP_w182.

Browse all APP alert codes