Skip to content

APP_w186 — R Pillar Camera Stream Exit

Full alert identifier: APP_w186_rPillarCameraStreamExit

Alert description

The right pillar camera stream to the Autopilot electronic control unit (ECU) exits or is interrupted, which may cause Autopilot functionality to be limited or unavailable.

Potential impact

Autopilot functionality may be limited or unavailable.

Set condition

The right pillar camera stream exits or is interrupted.

Clear condition

The right pillar camera stream returns.

Signals to check

These diagnostic fields are associated with APP_w186. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Buffer Error APP_sw186_bufferError —
Current Temperature APP_sw186_currentTemperature
255
SNA
degC
Deser Crc Error APP_sw186_deserCrcError —
Deser Line Length Error APP_sw186_deserLineLengthError —
Deser Lock Error APP_sw186_deserLockError —
Deser Parity Error APP_sw186_deserParityError —
Exit Status APP_sw186_exitStatus
0
NOMINAL
1
FAULT
—
First Frame Grab Failure APP_sw186_firstFrameGrabFailure —
Show 8 more fields
Signal Unit
Frame Grab Failure APP_sw186_frameGrabFailure —
Gain Control Failure APP_sw186_gainControlFailure —
Imager Heartbeat APP_sw186_imagerHeartbeat
0
NOMINAL
1
STATIC
3
SNA
—
Max Temperature APP_sw186_maxTemperature
255
SNA
degC
Min Temperature APP_sw186_minTemperature
255
SNA
degC
Num Capture Recoveries APP_sw186_numCaptureRecoveries —
Serializer Crc Err Count APP_sw186_serializerCrcErrCount
255
SNA
—
Temp Monitor Failure APP_sw186_tempMonitorFailure
0
MONITOR NO FAILURE
1
OUT OF SPEC
2
MONITOR OTHER FAILURE
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of APP_w186.

Browse all APP alert codes