APP_w136 — L Pillar Cam Init Fault
Full alert identifier: APP_w136_lPillarCamInitFault
Alert description
When the Autopilot electronic control unit (ECU) boots, the left pillar camera is unable to initialize.
Potential impact
Autopilot features are unavailable or limited
Set condition
When the Autopilot ECU boots, communication cannot be established with the left pillar camera.
Clear condition
Communication issue is rectified with the left pillar camera, ECU is rebooted, and camera is initialized.
Signals to check
These diagnostic fields are associated with APP_w136. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
L Pillar Cam Deser Fault
APP_
|
— |
L Pillar Cam I 2 Cbus Fault
APP_
|
— |
L Pillar Cam Sensor Fault
APP_
|
— |
L Pillar Cam Ser Fault
APP_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of APP_w136.