TAS Normal Mode
Tesla Air Suspension (TAS) Electronic Control Unit (ECU) enters normal mode.
PROC_TAS_X_ENTER-NORMAL-MODE
Find the procedure. Understand what it does.
Explore diagnostic tests and repair tasks you can run with Tesware on compatible vehicles.
1,357
service tasks
Model 3, Y, S & X
665 tasks Showing 601–624
Clear filtersTesla Air Suspension (TAS) Electronic Control Unit (ECU) enters normal mode.
PROC_TAS_X_ENTER-NORMAL-MODE
Calibrates the ride height of the Tesla Air Suspension (TAS).
PROC_TAS_X_CALIBRATE-RIDE-HEIGHT
Checks the ride height calibration of the Tesla Air Suspension (TAS).
PROC_TAS_X_CHECK-RIDE-HEIGHT-CALIBRATION
Tesla Air Suspension (TAS) Electronic Control Unit (ECU) enters Service Mode.
PROC_TAS_X_ENTER-SERVICE-MODE
Check Tesla Air Suspension (TAS) airline connections. TAS must be in Service Mode (PROC_TAS_X_ENTER-SERVICE-MODE) and be set to Medium ride height (PROC_TAS_X_LEVEL-TO-HEIGHT) before running this routine.
PROC_TAS_X_AIRLINE-TEST
Tests if the Front Controllers is able to turn on its Drive inverter front efuse successfully.
PROC_VCFRONT2_DIF-EFUSE-TURN-ON-TEST
A all-in-one test for the exterior lights on the Model X. During the test, all front or rear exterior lights will illuminate for 5 seconds and the front or rear body controller will look for any errors. Pass or fail results will be returned for every light. Note: the park lights (hockey sticks) and turn signals will turn on at the same time and the color will be peach (mix of orange and white). This is expected.
PROC_BCFRONT_FRONT_TEST-FRONT-LIGHTS
A all-in-one test for the exterior lights on the Model X. During the test, all of the front exterior lights will illuminate for 5 seconds and the front body controller will look for any errors. Pass or fail results will be returned for every light. Note: the front park lights (hockey sticks) and turn signals will turn on at the same time and the color will be peach (mix of orange and white). This is expected.
PROC_BCREAR_REAR_TEST-REAR-LIGHTS
Starts the Thermal Coolant Flow Cycle with all coolant modes. The routine will run for up to 20 minutes.
PROC_VCFRONT2_X_THERMAL-COOLANT-FLOW-CYCLE
Starts the Thermal Coolant Flow Cycle with all coolant modes. The routine will run for up to 20 minutes.
PROC_VCFRONT_X_THERMAL-COOLANT-FLOW-CYCLE
HEATPUMP ONLY: Starts the Thermal Coolant Flow Cycle with only ambient source mode. The routine will run for up to 5 minutes
PROC_VCFRONT2_X_THERMAL-COOLANT-FLOW-CYCLE-AMBIENT-SOURCE
HEATPUMP ONLY: Starts the Thermal Coolant Flow Cycle with only ambient source mode. The routine will run for up to 5 minutes
PROC_VCFRONT_X_THERMAL-COOLANT-FLOW-CYCLE-AMBIENT-SOURCE
PRE-HEATPUMP ONLY: Starts the Thermal Coolant Flow Cycle with only parallel bypass mode. The routine will run for up to 5 minutes
PROC_VCFRONT_X_THERMAL-COOLANT-FLOW-CYCLE-PARALLEL-BYPASS
Starts the Thermal Coolant Flow Cycle with only parallel mode. The routine will run for up to 5 minutes
PROC_VCFRONT2_X_THERMAL-COOLANT-FLOW-CYCLE-PARALLEL-NO-BYPASS
Starts the Thermal Coolant Flow Cycle with only parallel mode. The routine will run for up to 5 minutes
PROC_VCFRONT_X_THERMAL-COOLANT-FLOW-CYCLE-PARALLEL-NO-BYPASS
Starts the Thermal Coolant Flow Cycle with only series bypass mode. The routine will run for up to 5 minutes
PROC_VCFRONT2_X_THERMAL-COOLANT-FLOW-CYCLE-SERIES-BYPASS
Starts the Thermal Coolant Flow Cycle with only series bypass mode. The routine will run for up to 5 minutes
PROC_VCFRONT_X_THERMAL-COOLANT-FLOW-CYCLE-SERIES-BYPASS
Starts the Thermal Coolant Flow Cycle with only series mode. The routine will run for up to 5 minutes
PROC_VCFRONT2_X_THERMAL-COOLANT-FLOW-CYCLE-SERIES-NO-BYPASS
Starts the Thermal Coolant Flow Cycle with only series mode. The routine will run for up to 5 minutes
PROC_VCFRONT_X_THERMAL-COOLANT-FLOW-CYCLE-SERIES-NO-BYPASS
Starts or stops the coolant and/or refrigerant fluid fill and drain routine. 'Start' will set the coolant valve to Series mode with the radiator 50% bypassed, chiller valve 50% bypassed, and all coolant pumps off. This routine fully opens the chiller evaporator expansion valve and chiller solenoid (if equipped). It also disables the refrigerant compressor. This routine fails if another routine is already running on the Thermal Controller or if the vehicle is charging or in Drive. 'Stop' will cancel the fluid fill and drain routine and restore normal operation. Stopping this routine will fail if it is already stopped.
PROC_THC_X_FLUID-FILL-DRAIN
Places the coolant valve in series mode and turns the coolant pumps off for draining or filling coolant. In addition, this routine opens the Electronic Expansion Valves (EXVs) for recovering or charging refrigerant.
PROC_VCFRONT_X_THERMAL-FILL-DRAIN
Runs the thermal system test for approximately five minutes and returns results. Results can be retrieved at a later time using PROC_THC_X_THERMAL-TEST-RESULT.
PROC_THC_X_THERMAL-TEST
Request thermal test result
PROC_THC_X_THERMAL-TEST-RESULT
Attempts to moves the third row seat recliner according to the provided command.
PROC_VC_X_3R-SEAT-RECLINE-COMMAND-MOVEMENT