GTW Reboot
Reboots the Gateway (GTW).
PROC_ICE_X_GATEWAY-SAFE-REBOOT
Find the procedure. Understand what it does.
Explore diagnostic tests and repair tasks you can run with Tesware on compatible vehicles.
1,357
service tasks
Model 3, Y, S & X
676 tasks Showing 289–312
Clear filtersReboots the Gateway (GTW).
PROC_ICE_X_GATEWAY-SAFE-REBOOT
Formats the Gateway (GTW) SD card
PROC_ICE_X_FORMAT-SD-CARD
Requests Gateway (GTW) and User Interface (UI) reboot once vehicle is parked and displays are off.
PROC_ICE_X_STANDBY-REBOOT-GTW
Tests for power, connection, and communication of the heat pump expansion valve (EXV) controlled by the Front Vehicle Controller (VCFRONT).
TEST-SELF_VCFRONT_X_EXVS
Tests for power, connection, and communication of the heat pump sequential expansion valve (EXV) controlled by the Front Vehicle Controller (VCFRONT).
TEST-SELF_VCFRONT_X_EXV-SEQUENTIAL-CALIBRATION
Commissions the Heat Pump Thermal System by opening expansion valves and slowly ramping the compressor to distribute oil.
TEST-SELF_VCFRONT_X_HEAT-PUMP-COMMISSIONING
Starts the Heat Pump Thermal System Commissioning and returns. The routine will run for up to 1 minute, but the final results are not reported
TEST-SELF_VCFRONT_X_HEAT-PUMP-COMMISSIONING-START
Stops the Heat Pump Thermal System Commissioning and returns.
TEST-SELF_VCFRONT_X_HEAT-PUMP-COMMISSIONING-STOP
This self test checks SWC Heater functionality
TEST-SELF_VCLEFT_X_SWC-HEATER
Updates HomeLink configuration. If the HomeLink icon does not appear in the controls panel after the reboot, exit and lock the vehicle to initiate another reboot.
PROC_VCFRONT_X_HOMELINK-RETROFIT
Tests Local Interconnect Network (LIN) connections to the HomeLink Electronic Control Unit (ECU). This routine takes a few seconds.
TEST-SELF_VCFRONT_X_HOMELINK
Checks whether the horn is properly installed and connected.
TEST-SELF_VCFRONT_X_HORN
Discharges the High Voltage (HV) Battery using a compatible V3 Supercharger.
PROC_HV_X_SUPERDISCHARGE
Requests the results from the HV Pack Hot Seal Test Routine and returns successul if the routine ran to completion.
TEST-SELF_VCFRONT_X_THERMAL-HV-PACK-HOT-SEAL-RESULTS
Starts the HV Pack Hot Seal Test Routine. The routine will run for up to 50 minutes
TEST-SELF_VCFRONT_X_THERMAL-HV-PACK-HOT-SEAL-START
Stops the HV Pack Hot Seal Test Routine. The routine will run for up to 50 minutes
TEST-SELF_VCFRONT_X_THERMAL-HV-PACK-HOT-SEAL-STOP
Tests the connectivity of the HVAC blower motor to the right vehicle controller (VCRIGHT) ECU.
TEST-SELF_VCRIGHT_X_HVAC-BLOWER
Tests for power, connection, and communication of the Heating, Ventilation and Air Conditioning (HVAC) blower controlled by the Left Vehicle Controller (VCLEFT).
TEST-SELF_VCLEFT_X_HVAC-BLOWER
Tests HVAC case door actuator functionality and returns a pass / fail result. This is the same routine used by Tesla in the manufacturing environment to certify HVAC case actuators are performing to specification.
TEST-SELF_VCRIGHT_X_HVAC-CASE-ACTUATORS
Tests for power, connection, and communication of the Heating, Ventilation and Air Conditioning (HVAC) compressor controlled by the Front Vehicle Controller (VCFRONT).
TEST-SELF_VCFRONT_X_HVAC-COMPRESSOR-PING
Runs the HVAC Refrigerant Distribution task.
PROC_VCRIGHT_X_THERMAL-HVAC-REFRIGERANT-DISTRIBUTION
Starts the HVAC Refrigerant Distribution task.
PROC_VCRIGHT_X_THERMAL-HVAC-REFRIGERANT-DISTRIBUTION-START
Stops the HVAC Refrigerant Distribution task.
PROC_VCRIGHT_X_THERMAL-HVAC-REFRIGERANT-DISTRIBUTION-STOP
This routine tests the cabin HVAC operation (cabin heating and cooling) and returns pass or fail. This is the same routine used by Tesla factory EOL to certify the cabin HVAC is performing to specification.
TEST-SELF_VCRIGHT_X_HVAC-PERFORMANCE