Skip to content
Diagnostic tests 2026 firmware

Coolant Air Purge

Gen3/tasks/TEST_VCFRONT_X_THERMAL-COOLANT-AIR-PURGE

What this task does

Powers the accessory rail and runs HVAC pumps at maximum speed, changing valve positions. Estimated time to complete is 10 minutes. Make sure the gateway remains unlocked for at least 12 minutes (720 seconds). To exit the routine early, run this routine again with STOP as the input. The controller will continue to run coolant air purge until it is completed or is requested to stop.

Vehicle & firmware coverage

Open a version to see its description, requirements, and input definitions. Hardware configuration and live vehicle checks also determine availability.

Model 3 / Y AMD · Firmware 2026.32.3
Vehicle coverage
2024+ Model 3, 2025+ Model Y, Model Y, Pre-2024 Model 3
Supported connection
Local connection
Vehicle state
Stationary · Parked
Gateway diagnostic level
Service, Factory, DiagLinkActive

Task inputs (1)

Coolant Air Purge Control

mode · String

START will start the routine and poll for results, STATUS returns the current active status, STOP will stop the routine if it is running.

Firmware default: START

Options: START, STATUS, STOP

Model 3 / Y Intel · Firmware 2026.32.7
Vehicle coverage
Model Y, Pre-2024 Model 3
Supported connection
Local connection
Vehicle state
Stationary · Parked
Gateway diagnostic level
Service, Factory, DiagLinkActive

Task inputs (1)

Coolant Air Purge Control

mode · String

START will start the routine and poll for results, STATUS returns the current active status, STOP will stop the routine if it is running.

Firmware default: START

Options: START, STATUS, STOP

Model S / X (2021+) AMD · Firmware 2026.20.6.1
Vehicle coverage
2021+ Model S, 2021+ Model X
Supported connection
Local connection
Vehicle state
Stationary · Parked
Gateway diagnostic level
Service, Factory, DiagLinkActive

Task inputs (1)

Coolant Air Purge Control

mode · String

START will start the routine and poll for results, STATUS returns the current active status, STOP will stop the routine if it is running.

Firmware default: START

Options: START, STATUS, STOP

Browse all tasks →
Service procedures

12V Reset

Power cycles all of the eFuses on the Vehicle Front Controller (VCFRONT) and shuts off Sleep Bypass.

PROC_VCFRONT_X_12V-RESET

Model 3 / Y
Self-tests

Active Louver Self Test

Performs louver connection check. Will only move the louver through partial range of motion.

TEST-SELF_VCFRONT_X_ACTIVE-LOUVER

Model 3 / Y
Service procedures

Allow High Beam Enablement in Factory Mode

Allows high beams to be enabled in Factory Mode until the Front Vehicle Controller (VCFRONT) ECU is power cycled.

PROC_VCFRONT_X_ALLOW-HIGH-BEAMS-FACTORY

Model S / X (2021+)
Self-tests

Ambient Sensor Test

Tests for power, connection, and communication of the ambient sensor controlled by the Front Vehicle Controller (VCFRONT).

TEST-SELF_VCFRONT_X_AMBIENT-TEMP

Model 3 / Y Model S / X (2021+)