2nd and 3rd Row Seat Fold Flat Switch Connection Test
Tests electrical connection of the 2nd row and 3rd row seat fold flat switchpack.
TEST-SELF_VCLEFT_X_2R-3R-SEAT-DUMP-SWITCH
Gen3/tasks/TEST-SELF_VCLEFT_X_LIFTGATE-ENSURES-CLOSED-AT-BEGINNING
If liftgate is open when test is requested, liftgate will actuate to close before starting test sequence
Open a version to see its description, requirements, and input definitions. Hardware configuration and live vehicle checks also determine availability.
Will open and close the liftgate. If already open, will close, open, and close. Ensure the area is clear.
No user inputs are listed in this firmware.
Will open and close the liftgate. If already open, will close, open, and close. Ensure the area is clear.
No user inputs are listed in this firmware.
Will open and close the liftgate. If already open, will close, open, and close. Ensure the area is clear.
No user inputs are listed in this firmware.
Tests electrical connection of the 2nd row and 3rd row seat fold flat switchpack.
TEST-SELF_VCLEFT_X_2R-3R-SEAT-DUMP-SWITCH
Tests the connection between VCLEFT and the different rear left seat endpoints.
TEST-SELF_VCLEFT_REAR_SEAT
Tests the second row (2R) left recline and center armrest console switches, motors, and sensors by measuring current draw, performing endpoint tests, and detecting communication with the Local Interconnect Network (LIN) bus.
TEST-SELF_VCLEFT_2R_P2-MS-RECLINE-ARMREST-CONSOLE
Tests the functionality and connectivity of the first row left airwave actuators to the left vehicle controller (VCLEFT) ECU.
TEST-SELF_VCLEFT_X_AIRWAVE-FIRST-ROW-LEFT