12V Reset
Power cycles all of the eFuses on the VCFRONT and VCBATT and shuts off Sleep Bypass.
PROC_VCBATT1_X_12V-RESET
Gen3/tasks/TEST-SELF_VCBATT1_X_LV-PROTECTIONS
Performs a series of self-tests of the low voltage protections
Open a version to see its description, requirements, and input definitions. Hardware configuration and live vehicle checks also determine availability.
Will block drive for a short time while internal self-tests execute.
No user inputs are listed in this firmware.
Will block drive for a short time while internal self-tests execute.
No user inputs are listed in this firmware.
Power cycles all of the eFuses on the VCFRONT and VCBATT and shuts off Sleep Bypass.
PROC_VCBATT1_X_12V-RESET
Disable running of Low Voltage Protection Self Tests in the factory.
PROC_VCBATT1_X_DISABLE-FACTORY-LV-PROTECTION-SELF-TESTS
Enable running of Low Voltage Protection Self Tests in the factory.
PROC_VCBATT1_X_ENABLE-FACTORY-LV-PROTECTION-SELF-TESTS
Tests communication with the front vehicle controller (VCBATT1) Electronic Control Unit (ECU). Communication is established via Unified Diagnostics Services (UDS) over the Controller Area Network (CAN).
PING-TP_VCBATT1