Skip to content
Service procedures 2026 firmware

All Window Command Position

Gen3/tasks/PROC_VC_X_ALL-COMMAND-WINDOW-POSITION

What this task does

Move all windows to a specified position.

Vehicle & firmware coverage

Open a version to see its description, requirements, and input definitions. Hardware configuration and live vehicle checks also determine availability.

Model 3 / Y AMD · Firmware 2026.32.3
Vehicle coverage
2024+ Model 3, 2025+ Model Y, Model Y, Pre-2024 Model 3
Supported connection
Local connection
Vehicle state
Stationary · Drive; Stationary · Neutral; Stationary · Parked; Stationary · Reverse
Gateway diagnostic level
No specific level listed

Procedure notes

This routine will actuate all windows.

Task inputs (1)

Target Window Position

POSITION · Int

Desired window position percent 0 (closed) to 100 (open).

Firmware default: 0

Model 3 / Y Intel · Firmware 2026.32.7
Vehicle coverage
Model Y, Pre-2024 Model 3
Supported connection
Local connection
Vehicle state
Stationary · Drive; Stationary · Neutral; Stationary · Parked; Stationary · Reverse
Gateway diagnostic level
No specific level listed

Procedure notes

This routine will actuate all windows.

Task inputs (1)

Target Window Position

POSITION · Int

Desired window position percent 0 (closed) to 100 (open).

Firmware default: 0

Model S / X (2021+) AMD · Firmware 2026.20.6.1
Vehicle coverage
2021+ Model S, 2021+ Model X
Supported connection
Local connection
Vehicle state
Stationary · Drive; Stationary · Neutral; Stationary · Parked; Stationary · Reverse
Gateway diagnostic level
No specific level listed

Procedure notes

This routine will actuate all windows.

Task inputs (1)

Target Window Position

POSITION · Int

Desired window position percent 0 (closed) to 100 (open).

Firmware default: 0

Browse all tasks →
Service procedures

Actuate Thermal Components

Set Thermal components to target positions for one minute or sweep them twice between end points. The routine will complete when all components have reached their target positions. Until then, other components will remain at their target positions or continue sweeping. Unselected components will default to a target position that minimizes noise, vibration, and harshness (NVH).

PROC_VC_X_ACTUATE-THERMAL-COMPONENTS

Model S / X (2021+)
Service procedures

Actuate Thermal Components

Set Thermal components to target positions for one minute or sweep them twice between end points. The routine will complete when all components have reached their target positions. Until then, other components will remain at their target positions or continue sweeping. Unselected components will default to a target position that minimizes noise, vibration, and harshness (NVH).

PROC_VC_X_ACTUATE-THERMAL-COMPONENTS

Model 3 / Y