12 Volt Battery Reset
Power cycles all of the eFuses on the VCFRONT and VCBATT ECUs and shuts off Sleep Bypass.
PROC_VCBATT_X_12V-RESET
Coriander/tasks/TEST-SELF_VCBATT_X_COOLANT-PUMP-BATTERY
Tests if the battery coolant pump is electrically connected and operating as expected. The pump will be activated and the Vehicle Battery Controller (VCBATT) will monitor current feedback to verify proper electrical connection.
Open a version to see its description, requirements, and input definitions. Hardware configuration and live vehicle checks also determine availability.
The battery coolant pump will be activated and may make noise.
No user inputs are listed in this firmware.
Power cycles all of the eFuses on the VCFRONT and VCBATT ECUs and shuts off Sleep Bypass.
PROC_VCBATT_X_12V-RESET
Clear all left headlamp factory latched faults that were triggering leftHeadlampFactoryFault alert
PROC_VCBATT_X_CLEAR-LEFT-HEADLAMP-LATCHED-FACTORY-FAULTS
Tests the communication of the left headlamp module with the VCBATT ECU.
TEST-SELF_VCBATT_L_HCM
TEST-SELF_VCBATT_X_LVBMS
TEST-SELF_VCBATT_X_LVBMS