VCSEATD_a010 — Ext Supply Volt Error

Full alert identifier: VCSEATD_a010_ExtSupplyVoltError

Alert description

The vehicle controller detects the supply voltage from 1 or more components is outside of the expected range.

Potential impact

Features depending on the vehicle controller functionality may be unavailable or may not function as expected.

Set condition

The vehicle controller detects the supply voltage from 1 or more components is < 7.31. Alert log signal data should provide more information on the specific condition(s) detected.

Clear condition

The vehicle controller detects the supply voltage from all components is > 7.31 V.

Signals to check

These diagnostic fields are associated with VCSEATD_a010. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Under Volt Detected VCSEATD_a010_UnderVoltDetected —
Under Volt Timeout VCSEATD_a010_UnderVoltTimeout —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCSEATD_a010.