VCRIGHT_a538 — Hvac System Not Nominal

Full alert identifier: VCRIGHT_a538_hvacSystemNotNominal

Alert description

The right vehicle controller (VCRIGHT) detects the HVAC system is not nominal due to a condition, which may cause Climate Keeper Mode functionality to be limited or unavailable.

Potential impact

Climate Keeper Mode functionality may be limited or unavailable.

Set condition

The VCRIGHT detects the HVAC system is not nominal for 30 seconds due to a condition. Alert log signal data should provide more information on the specific condition(s) detected.

Clear condition

The VCRIGHT does not detect a condition on the HVAC system for 10 seconds, allowing the HVAC system to be nominal.

Signals to check

These diagnostic fields are associated with VCRIGHT_a538. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Airpaths Blocked VCRIGHT_a538_airpathsBlocked —
Blower Fault Or Stopped VCRIGHT_a538_blowerFaultOrStopped —
Cabin Model Not Initialized VCRIGHT_a538_cabinModelNotInitialized —
Cabin Temp Sensor Fault VCRIGHT_a538_cabinTempSensorFault —
Compressor Fault Or Standby VCRIGHT_a538_compressorFaultOrStandby —
Duct Temp Sensor Fault VCRIGHT_a538_ductTempSensorFault —
Evap Temp Sensor Fault VCRIGHT_a538_evapTempSensorFault —
Heat Pump Mode Not Attainable VCRIGHT_a538_heatPumpModeNotAttainable —
Show 6 more fields
Signal Unit
Hv On VCRIGHT_a538_hvOn —
Hvac Power On VCRIGHT_a538_hvacPowerOn —
Limp Mode VCRIGHT_a538_limpMode —
Ptc Heater Fault VCRIGHT_a538_ptcHeaterFault —
Ths Mia VCRIGHT_a538_thsMia —
Ths Version Mismatch VCRIGHT_a538_thsVersionMismatch —