VCRIGHT_a495 — Center High Mount Stop Light Fault

Full alert identifier: VCRIGHT_a495_centerHighMountStopLightFault

Alert description

A condition affecting Center High Mounted Stop Light (CHMSL) functionality has been detected.

Potential impact

The CHMSL may be partially or fully unlit when the vehicle is braking

Set condition

The vehicle controller detects the CHMSL is unplugged, does not draw current when on, or its efuse is tripped

Clear condition

The light is plugged in, draws current when on, and its efuse is not tripped

Signals to check

These diagnostic fields are associated with VCRIGHT_a495. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Current Sense Faulted VCRIGHT_a495_currentSenseFaulted —
Output Faulted VCRIGHT_a495_outputFaulted —
Over Current VCRIGHT_a495_overCurrent —
Over Temperature VCRIGHT_a495_overTemperature —
Temp Sense Faulted VCRIGHT_a495_tempSenseFaulted —
Under Current VCRIGHT_a495_underCurrent —