VCRIGHT_a494 — Falcon ECU Voltage Mismatch

Full alert identifier: VCRIGHT_a494_falconECUVoltageMismatch

Alert description

There is a greater than 0.5V drop between input power to the right vehicle controller and the Falcon ECU circuit.

Potential impact

Potential hardware issue could cause eFuse to trip or VOR.

Set condition

0.5V difference between input voltage to the board and the eFuse.

Clear condition

Less than 0.5V difference between input voltage to the board and the eFuse

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
E Fuse Voltage VCRIGHT_a494_eFuseVoltage V
Vbat Prot Voltage VCRIGHT_a494_vbatProtVoltage V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCRIGHT_a494.