VCRIGHT_a345 — HVAC PTC Heater Pwr eFuse Fault

Full alert identifier: VCRIGHT_a345_HVACPTCHeaterPwrEFuseFault

Alert description

The current sense for the HVAC PTC heater is saturated to maximum sensable value

Potential impact

Potential short condition on the PTC, THS, or Glove Box LED circuits

Set condition

ADC is saturated to maximum value detectable for PTC, THS, Glove Box HSD

Clear condition

PTC heater power Efuse if no longer faulted

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
PTCTHSGB Pwr Current VCRIGHT_a345_PTCTHSGBPwrCurrent A

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCRIGHT_a345.