Skip to content

VCRIGHT_a237 — Lumbar Over Pres B

Full alert identifier: VCRIGHT_a237_lumbarOverPresB

Alert description

The bladder B has exceeded pressure limits

Potential impact

Damage to bladder or valve block

Set condition

Bladder pressure exceeds 1300hPa (absolute)

Clear condition

Bladder B does not exceed pressure limit

Signals to check

These diagnostic fields are associated with VCRIGHT_a237. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Lumbar A Pressure Hpa VCRIGHT_a237_lumbarAPressureHpa —
Lumbar A State VCRIGHT_a237_lumbarAState
0
STOPPED
1
MOVING UP
2
MOVING DOWN
3
RECALLING
4
CALIBRATING
5
UNDEFINED
—
Lumbar B Pressure Hpa VCRIGHT_a237_lumbarBPressureHpa —
Lumbar B State VCRIGHT_a237_lumbarBState
0
STOPPED
1
MOVING UP
2
MOVING DOWN
3
RECALLING
4
CALIBRATING
5
UNDEFINED
—
Lumbar Diag Status VCRIGHT_a237_lumbarDiagStatus —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCRIGHT_a237.

Browse all VCRIGHT alert codes