Skip to content

VCRIGHT_a225 — Seat Enc Stall Back

Full alert identifier: VCRIGHT_a225_seatEncStallBack

Alert description

The motor isn't providing encoder feedback

Potential impact

Memory recall will be unavailable

Set condition

Current draw is nonzero and not stalling but encoder values don't increase

Clear condition

The motor exits the motor stopped state

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Seat Motor Current VCRIGHT_a225_seatMotorCurrent A
Signal Unit
Seat Motor Calibrated VCRIGHT_a225_seatMotorCalibrated —
Seat Motor State VCRIGHT_a225_seatMotorState
0
STOPPED
1
MOVING UP
2
MOVING DOWN
3
RECALLING
4
CALIBRATING
5
UNDEFINED
—
Seat Switch Back VCRIGHT_a225_seatSwitchBack
0
SNA
1
OFF
2
ON
3
FAULT
—
Seat Switch Forward VCRIGHT_a225_seatSwitchForward
0
SNA
1
OFF
2
ON
3
FAULT
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCRIGHT_a225.

Browse all VCRIGHT alert codes